Features & Applications
The ENVIROMUX Server Environment Monitoring System monitors critical environmental conditions, such as temperature, humidity, liquid presence, motion, intrusion, and vibration. When a sensor goes out of range of a configurable threshold, the system will notify you via email, LEDs, alarm beacon, web page, network management (SNMP), voice phone calls (via Automatic Voice Dialer System), and SMS messages (via external GSM modem).
The system includes three internal sensors: temperature, humidity and power. It also supports 16 external configurable sensors and eight digital input sensors.
-
Monitor and manage server room environmental and security conditions over IP.
-
Create alarm signals with customized input parameters.
-
Four output relays for control of external devices.
-
Supports IP network video camera.
-
Live view of a facility from anywhere, anytime.
-
Seamlessly integrate into the ENVIROMUX.
-
Up to eight cameras can be associated with each ENVIROMUX.
-
One integrated view - see different Web cameras side-by-side with physical and environmental parameters
-
Monitor (ping) up to 64 IP network devices.
-
Provides power supply for all sensors.
-
Available with optional dual power for connection to two separate power sources.
-
If the first power source fails, the unit will automatically, without interruption, switch over to the second power source before switching to the battery backup.
-
Internal battery backup.
-
1RU rack mount case is standard.
-
Up to four units can be used together to increase the number of sensors connected.
-
Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.
Specifications

(Please click the image to enlarge)
1. Power Port
-
110 or 230 VAC at 50 or 60 Hz via IEC connector.
-
Connection for Earth Ground.
-
Fuse protection.
-
Optional dual power (not shown)
-
110 or 230 VAC at 50 or 60 Hz via IEC connector.
-
If the first power source fails, the unit will automatically, without interruption, switch over to the second power source before switching to the battery backup.
2. RJ45 Sensor Ports
-
Sixteen RJ45 modular jacks for connecting NTI temperature, humidity, temperature/humidity, liquid detection, smoke detection, glass break, vibration and motion sensors.
3. Digital Inputs
4. Output Relays
5. Beacon Port
6. Siren Port
7. Expansion Ports
8. Console Port
9. AUX Port
10. AUX Power Port
11. Ethernet Port
Protocols
-
HTTP, SNMP V1/V2c, SMTP, TCP/IP, Syslog, SNTP
-
Supports local authentication, SSL.
-
Operates and configures via HTTP/HTTPS web page, Telnet or RS232 interface.
-
Alerts are sent using email, SMS messages and/or SNMP traps when any monitored environmental condition exceeds a user-specified range.
-
Alerts are posted in message log, which is accessible through Web user interface. The log can be downloaded as a tab-delimited plain text file.
-
Sends notifications of alerts to a maximum of 17 email addresses, SNMP addresses and/or cell phone numbers. The users can configure the schedule when they will be alerted
Internal Temperature Sensor
Internal Humidity Sensor
Internal Power Sensor
-
Measures mains voltage: 0 to 255 VAC
-
Measures battery voltage: 0 to 20 VDC
-
Alerts are sent when there is a power outage and when power returns.
Back-up Battery
Dimensions
Environmental
-
Operating temperature: 32°F to 100°F (0°C to 38°C).
-
Storage temperature: -22°F to 140°F (-30°C to 60°C).
-
Operating and Storage Relative Humidity: 17 to 90% non-condensing RH.
Regulatory Approvals
Warranty
Control Methods
Web Interface
-
Full configuration via Web-page
-
Configure sensor thresholds and timing, alarm methods, alert formats and system data log.
-
View current sensor values and alert status.
-
View entries stored in the system data log.
-
Configure IP information (address, subnet mask, default gateway, DNS, etc.) and user administrative settings.
-
Administrate up to 16 users plus a root administrator.
-
Permissions, schedule and alert methods are configurable for each user.
-
Up to 8 users can access the web page at one time.
RS232 Control
-
Display and configure network settings (IP address, subnet mask, default gateway, DNS, SMTP, etc.), Enterprise settings, and time settings.
-
View current values and alert statuses for sensors/digital inputs/IP devices.
-
Configure SNMP
-
Serial baud rate: 9,600 to 115,200bps.
-
Data format: 1 start bit, 8 data bits, no parity, 1 stop bit.
Telnet
-
Display and configure network settings (IP address, subnet mask, default gateway, DNS, SMTP, etc.), Enterprise settings, and time settings.
-
View current values and alert statuses for sensors/digital inputs/IP devices.
-
Configure SNMP
-
Security is ensured by password.
Network Operation
Front Panel Interface
Sensor Data Graphs